LC1D15000F7C
1
  • LC1D15000F7C
2
views: 552

LC1D15000F7C

Rate:
0.0000/5

( 0 reviews )

Item NO.: V008651 MOQ: 0
Weight:    0kgs
Package Size:  
 Price:
$100.00
 Qty:
      $100.00
 Shipping:   Calculate Shipping Cost

ZZ

LC1D15000F7C

delivery time:in stock



Main information
Product range
TeSys Deca
Product range
TeSys Deca
product type
Contactor
Short product name
LC1D
Contactor application field
Applied to non inductive or micro inductive load and resistance furnace
Applied to AC load with power factor greater than or equal to 0.95
Use Category
AC-1
AC-3
AC-3e
Number of poles
3P
Rated operating voltage [Ue]
Power circuit:<=300 V DC
Power circuit:<=1000 V AC 25... 400 Hz
Rated working current [Ie]
200 A 60 ° C) on...<=440 V AC AC-1 for power circuit
150 A 60 ° C) on...<=440 V AC AC-3 for power circuit
[Uc] control circuit voltage
110 V AC 50/60 Hz
Supplementary information
Motor power (kW)
40 kW on 220/240 V AC 50/60 Hz (AC-3)
75 kW on... 380/400 V AC 50/60 Hz (AC-3)
80 kW on 415/440 V AC 50/60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
100 kW on 660/690 V AC 50/60 Hz (AC-3)
90 kW on 1000 V AC 50/60 Hz (AC-3)
22 kW on 400 V AC 50/60 Hz (AC-4)
model
LC1D
Loop contact type
3 NO
Protective cover
nothing
Agreed heating current [Ith]
200 A<60 ° C on
Rated short-time withstand current [Icw]
250 A at<40 ° C - 10 minutes for power circuit
1400 A<40 ° C on... - 1 s for power circuit
1200 A at<40 ° C - 10 s for power circuit
580 A<40 ° C on... - 1 minute for power circuit
Fuses for use with relays
315 A gG on
250 A gG on<=690 V with Type 2 applicable power circuit
Average impedance
0.6 m Ω - Ith 200 A 50 Hz applicable power circuit
Rated insulation voltage [Ui]
Power circuit: 1000 V in accordance with IEC 60947-4-1
Overvoltage category
III
class of pollution
three
Rated impulse withstand voltage [Uimp]
8 kV acc. to IEC 60947
Safety and reliability level
B10d=1369863 contactors with nominal load according to EN/ISO 13849-1
B10d=20000000 mechanical load contactors in accordance with EN/ISO 13849-1
Mechanical life
8 Mcycles
Electrical life
<=440 V at 0.6 Mcycles 250 A AC-1 Ue
<=440 V at 0.8 Mcycles 150 A AC-3 Ue
660/690 V at 1.5 Mcycles 90 A AC-3 Ue
Control loop characteristics
AC 50/60 Hz on
Surge suppression module
No built-in surge suppression module
Control voltage limit
0.3... 0.5 Uc - 40... 55 ° C release 50/60 Hz
0.8... 1.15 Uc - 40... 55 ° C operation 50/60 Hz
(~50Hz pull in) Power consumption (VA)
280…350 VA 50 Hz 0.9 20 °C)
280…350 VA 60 Hz 0.9 20 °C)
(~50Hz holding) Power consumption (VA)
2…18 VA 50 Hz 0.9 20 °C)
2…18 VA 60 Hz 0.9 20 °C)
Heat dissipation
3... 4.5 W 50/60 Hz on
Action time
20... 35 ms closed
40... 75 ms breaking
Maximum operating frequency
1200 times/hour<60 ° C on
Wiring capacity
Control circuit: bolt fastening 2 1... 2.5 mm ²  Cable selection: flexible cable with crimp terminal
Control circuit: bolt fastening 1 1... 2.5 mm ²  Cable selection: flexible cable with crimp terminal
Power circuit: bus terminal cable selection: hard wire bus cross-section: 5 x 25 mm
Power circuit: terminal 1 10... 120 mm ²  Outer diameter of lug Ø: 25 mm Cable type selection: flexible wire without cable terminal
Power circuit: terminal 2 10... 50 mm ²  Outer diameter of lug Ø: 25 mm Cable type selection: flexible wire without cable terminal
Power circuit: terminal 1 10... 120 mm ²  Outer diameter of lug Ø: 25 mm Cable selection: flexible cord with crimp terminal
Power circuit: terminal 2 10... 50 mm ²  Outer diameter of lug Ø: 25 mm Cable selection: flexible cord with crimp terminal
Power circuit: terminal 1 10... 120 mm ²  Outer diameter of lug Ø: 25 mm Cable selection: hard wire terminal without hoop wire
Power circuit: terminal 2 10... 50 mm ²  Outer diameter of lug Ø: 25 mm Cable selection: hard wire terminal without hoop wire
Control circuit: bolt fastening 1 1... 2.5 mm ²  Cable selection: flexible cable without cable terminal
Control circuit: bolt fastening 2 1... 2.5 mm ²  Cable selection: flexible cable without cable terminal
Control circuit: bolt fastening 1 1... 2.5 mm ²  Cable selection: hard wire without cable terminal
Control circuit: bolt fastening 2 1... 2.5 mm ²  Cable selection: hard wire without cable terminal
Tightening torque
Control circuit: 1.2 N.m, screw driver Ø 6, flat end for bolt fastening
Control circuit: 1.2 N.m screw driver No 2 cross screws for fastening by bolts
Power circuit: 12 N.m hexagon type 4 mm fastened by bolts
Power circuit: 12 N.m through cable connector hexagon type 13 mm screw: M8
Control circuit: 1.2 N.m screwdriver pozidriv No 2 for bolt fastening
Auxiliary contact type
Not included
Installation method
DIN-Rail Mounting 
Base plate installation
environment
standard
IEC 60947-4-1
GB 14048.4
Product certification
CCC
CE
UKCA
IP protection class
IP2x front panel main circuit is applicable to IEC 60529
IP2x front panel coil circuit is applicable to IEC 60529
Protective measures
TH according to IEC 60068-2-30
Ambient air temperature
-40... 60 ° C operation
60... 70 ° C with derating
-60... 80 ° C storage
Operating altitude
3000 m None
Fire resistance and abnormal high temperature resistance
850 ° C according to IEC 60695-2-11
Impact and vibration resistance
Seismic performance Contact opening (2 gn (5... 300 Hz)) in accordance with IEC 60068-2-6
Seismic performance Contact closing state (4 gn (5... 300 Hz)) in accordance with IEC 60068-2-6
Impact resistance 11 ms contact closing state (15 gn) in accordance with IEC 60068-2-27
Impact resistance 11 ms Contact opening (6 gn) acc. to IEC 60068-2-27
height
158 mm
width
120 mm
depth
136 mm
Net weight 
2.5 kg

 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Related tools
$39.00
$88.00
$1205.00
$346.00
$1162.00
$7.50
$44.00
Business time
9:00-22:00
  • Email:zorx@xaplc.com